![background image](http://html1.mh-extra.com/html/efka/dc-1500/dc-1500_instruction-manual_2367392070.webp)
EFKA FP220A5911
71
Function
with
control panel
V820
Tape cutter/Fast scissors at the start of the seam On/Off
1 key
Tape cutter/Fast scissors at the seam end On/Off
2 key
Light barrier On/Off
3 key
Chain suction On/Off
4 key
Blow fabric onto stack from light barrier uncovered onwards On/Off
5 key
Tape cutting at the seam end On/Off
6 key
Reverse motor rotation On/Off
7 key
Unlocking the chain On/Off
8 key
Sewing foot in the seam and/or at the seam end On/Off
9 key
Basic position 1 or 2
0 key
The
7
and
8
key settings on the V820 control panel have priority over the setting of parameter 019.
Functions
2 key
6 key
Tape cutting at the seam end Off, count c4 until stop
Off
Off
Tape cutting at the seam end On, count c4 until stop
On
Off
Tape cutting at the seam end Off, count c3 until stop
On/Off
On
Output and Times for Tape Cutter
Function
with
or
without
control panel
Parameter
Delay time for output M3 (ST2/27)
tape cutter
AH
(kd3)
284
ON period for
output M3 (ST2/27)
tape cutter
AH
(kt3)
285
!
Parameter
232
must be set at "
0
".
!
The delay time for the tape cutter is usually set at "0".
Output and Times for Fast Scissors
Function
with
or
without
control panel
Parameter
Delay time for output M3 (ST2/27)
fast scissors
AH1
(kd3)
284
ON period for output M3 (ST2/27)
fast scissors
AH1
(kt3)
285
Delay time for output M8 (ST2/24)
fast scissors
AH2
(kd4)
286
ON period for output M8 (ST2/24)
fast scissors
AH2
(kt4)
287
Selection of signal M8 functions
(m08)
296
!
Parameter
232
must be set at "
1
".
!
The delay times for "fast scissors" are usually set at "0".
Function “Blow Fabric onto Stack”
Function
with
or
without
control panel
Parameter
Function “blow fabric onto stack”
(bLA)
194
ON period for output M7
(kt5)
289
Parameter 194 = 0
Blow fabric onto stack (output M7) at the seam end over the time (kt5), which can be set by means
of parameter 289.
Parameter 194 = 1
Blow fabric onto stack (output M7) from light barrier uncovered to seam end; after the seam end
over the time (kt5).
See also List of Parameters chapter
“Timing Diagrams“
!
11.27 Manual Tape Cutter/Fast Scissors
Upon pressing an external key depending on the preselection of parameters 240...249, the
tape cutter
or
fast scissors
can
be enabled anywhere in the seam or at standstill.
See chapter
"Connection Diagram
" in the List of Parameters!