11.28 Manual Stacker
Function
with
or
without
control panel
Parameter
Stacker function with open/closed key
(iS1)
264
ON period for manual stacker
(ktS)
265
After pressing the key that has been allocated for the purpose, a stacker signal will be issued for a certain period of time
(parameter 265) at output M7 (socket ST2/23). Select the key by means of one of parameters 240...249. The manual stacker
function is possible in all modes except mode 16.
Parameter 240...249 = 26
Allocation of the key for the manual stacker signal.
Parameter 264 = 0
Signal “manual stacker” (output M7), when key is closed.
Parameter 264 = 1
Signal, “manual stacker” (output M7), when key is open.
Parameter 265
ON period of manual stacker signal.
11.29 Selection of Signals M8, M9 and M10 at the Start of the Seam
Function
with
or
without
control panel
Parameter
Signals M8, M9, M10 On/Off (0 = Off / 1 = On)
(ASi)
273
Delay time for signal M8 at the start of the seam
(Ad1)
274
Signal M8 ON period at the start of the seam
(At1)
275
Delay time for signal M9 at the start of the seam
(Ad2)
276
Signal M9 ON period at the start of the seam
(At2)
277
Delay time for signal M10 at the start of the seam
(Ad3)
278
Signal M10 ON period at the start of the seam
(At3)
279
Three different signals (M8, M9, M10) can be programmed for various applications at the start of the seam. These can be
enabled and disabled by means of parameter 273. Select delay times and ON periods by means of parameters 274...279.
11.30 Seam with Stitch Counting
Function
without
control panel
Parameter
Stitch counting On/Off
015
Function
with
control panel
V820
Stitch counting On/Off
2 key
11.30.1
Stitches for Stitch Counting
Function
with
or
without
control panel
Parameter
Number of stitches for a seam with stitch counting
(Stc)
007
The stitch counting stitches can be programmed and varied by means of the above parameters directly on the control or on
a connected V810/V820 control panel.
For fast operator information (HIT) when using the V820 control panel, the value of the function switched on by means of
the
2
key can be displayed for approx. 3 seconds. During this time, the value can be varied directly by pressing the
+
or
-
key.