![background image](http://html1.mh-extra.com/html/efka/dc-1500/dc-1500_instruction-manual_2367392041.webp)
EFKA FP220A5911
42
10.8 Positions
Function
with
or
without
control panel
Parameter
Selection according to position sensor
(PGm)
270
Number of angular degrees from the sensor position to position 2
(PGr)
271
Transmission ratio between motor shaft and machine shaft
(trr)
272
After setting parameter 270 at “1, 2, 3 or 4“ an angular degree must be selected by means of parameter 271, which
determines the stop in position 2 or 1 after the sensor position. The transmission ratio must already have been input by
means of parameter 272.
Connection of a sensor e. g. light barrier to socket B18/7. The following settings are possible using parameter 270:
Parameter 270 = 0
- The positions can be generated with the help of the transmitter incorporated in the motor and can be
set by means of parameter 171.
Parameter 270 = 1
- Setting the sensor to position 2.
- Position 1 is set according to the angular degree setting by means of parameter 271.
- Start measuring from leading edge position 2.
- 0V at input B18/7 (inside of the window)
- +5V at input B18/7 (outside of the window)
Parameter 270 = 2
- Setting the sensor to position 2.
- Position 1 is set according to the angular degree setting by means of parameter 271.
- Start measuring from trailing edge position 2.
- Input and output level as with setting “1“
Parameter 270 = 3
- Setting the sensor to position 1.
- Position 2 is set according to the angular degree setting by means of parameter 271.
- Start measuring from leading edge position 1.
- Input and output level as with setting “1“
Parameter 270 = 4
- Setting the sensor to position 1.
- Position 2 is set according to the angular degree setting by means of parameter 271.
- Start measuring from trailing edge position 1.
- Input and output level as with setting “1“
Parameter 270 = 5
- There is no position sensor. The drive stops unpositioned. The thread trimmer is suppressed.
= 0V
O U T
O U T
O U T
O U T
ST2
IN
P O S 1
S T2 / 2 0
P O S 2
S T2 / 2 0
P O S 1
S T2 / 2 1
P O S 2
S T2 / 2 1
P O S 1
S T2 / 2 1
S T2 / 2 0
P O S 2
S T2 / 2 0
P O S 1
P O S 2
S T2 / 2 1
P O S
B 1 8 / 7
S EN
= high
0 2 5 6 / S EN - 1
P a 2 7 1
P a 2 7 1
P a 2 7 1
P a 2 7 1
3 6 0 °
27
0 =
1
27
0 =
3
27
0 =
4
27
0 =
2
+ 5 V
0 V