- AB600A5015
Instruction Manual
- 8 -
With SIR you can do the most important settings for initial operation with menu prompting.
For safety reasons, the menu must be executed point by point. This ensures correct setting of all important
parameters.
Input of the code number for the fitting level.
Parameter
500
is displayed.
Parameter
290
for functional sequence of the cutting procedures.
Parameter
467
for selection of motor.
Parameter
111
for the maximum speed.
Parameter
161
for direction of motor rotation.
Parameter
270
for type of position sensor.
Parameter
272
for transmission ratio.
Important!
The transmission ratio should be determined and
indicated as precisely as possible.
If parameter
270 =0 or 5
, continue with input of
451
.
Check the transmission ratio.
Move pedal forwards. Let the drive run until ready (rdy) is displayed.
Press pedal to position 0. The check is complete.
if parameter
270 = 6
, set the reference position.
Turn hand wheel until symbol
o
display goes off.
Set reference position (e.g. height of the stitch plate, lower dead point).
Parameter
451
for position 1.
Parameter
453
for position 2.
To repeat the cycle from parameter
290
, push button
E.
Or end with button
P
(2x).
The values can be varied by pressing key +/-.
The input of the code number is described in the general operating manual!