- AB600A5015
Parameter List
- 52 -
12.2 Technical level
(Code no. 1907)
Parameters Designation
Unit
Max
Min
Preset
Ind.
100
SSc Number of softstart stitches
Stitches
254
0
2
110
n1 Positioning speed for threading (mode 66)
RPM
390
70
200
111
n2 Upper limit setting range of the maximum speed
RPM
9900
n2_
5000
114
n5 Speed after light barrier sensing
RPM
9900
200
1200
115
n6 Softstart speed
RPM
9900
70
500
116
n7 Trimming speed
RPM
700
70
200
118
n12 Automatic speed for stitch counting
RPM
9900
400
3500
119
nSt Speed stage graduation
1 = Linear
2 = Slightly progressive
3 = Highly progressive
3
1
121
n2 Lower limit setting range of the maximum speed
RPM
n2_
200
400
122
n9 Limited speed n9
RPM
9900
200
2000
128
ASd Start delay, when
command “start” is given by covering
the light barrier (see parameter 129)
ms
2000
0
0
129
ALS Machine start by covering the light barrier (only in conjunction with
parameter 132 = 1)
0 = Function Off
1 = Light barrier covered
pedal forward (>1)
machine run pedal
controlled.
2 = Pedal forward (>1)
light barrier covered machine run
pedal
controlled.
3 = Light barrier covered
machine run at automatic speed n12
(without pedal)
4 = Pedal forward (>1)
light barrier covered machine run
pedal
controlled.
5 = Light barrier covered
machine run at automatic speed n12
(without pedal)
Attention!
If 129 = 3, the machine starts immediately after covering
the light barrier without influence by the pedal! It can be stopped only
by uncovering the light barrier or by machine run blockage!
If machine run blockage is disabled, the machine starts immediately
even if the light barrier is still covered!
6 = The same as 3, run without pedal when covering the light
curtain, however start up only when FI is lowered.
3
0
0
130
LSF Light barrier filter for knitted fabrics
1
0
0
131
LSd 0 =
Light barrier sensing “covered”
1 = Light barrier sensing uncovered
1
0
1
132
LSS 0 = Machine start possible with light barrier uncovered or covered.
1 = Machine start blocked with light barrier uncovered if parameter
131 = 1.Machine start blocked with light barrier covered,
1
0
1
133
LSE Thread trimming operation, when completing the seam after light
barrier sensing On/Off
1
0
1
134
SSt Softstart On/Off
1
0
0
140
dnE Delay of seam end with pedal in pos. -2
ms
2550
0
0
141
SGn Speed status for the seam with stitch counting
0 = Speed controllable by the pedal up to the set maximum speed
(Parameter 111)
1 = Fixed speed (Parameter 118) without influence by the pedal
(machine stop by pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to the set limit
(Parameter 118)
3 = At fixed speed (Parameter 118) can be interrupted by full
heelback -2
4 = At fixed speed (Parameter 110) can be interrupted by full
heelback -2
4
0
0
142
SFn Speed status for the free seam and for the seam with light barrier
0 = Speed controllable by the pedal up to the set maximum speed
(Parameter 111)
1 = Fixed speed (Parameter 118) without influence by the pedal
(machine stop by pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to the set limit
(Parameter 118)
3 = At fixed speed (Parameter 118) can be interrupted by full
heelback (only for seams with light barrier).
3
0
0
153
brt Braking power at machine standstill
50
0
15
Содержание AB600A5015
Страница 5: ... AB AB600A5015 Instruction Manual 5 ...
Страница 60: ......
Страница 61: ...Instruction Manual with parameter List Distribution For your notes ...
Страница 62: ... Parameter list 94 For your notes ...
Страница 63: ... AB620A5030 5032 Parameter list 95 For your notes ...