- AB600A5015
Parameter List
- 53 -
Parameters Designation
Unit
Max
Min
Preset
Ind.
155
LSG Mode signal run
0 = Signal Off.
1 = Signal run On.
2 =
Signal “run” enabled when the speed is >3000 RPM.
3 = Signal with pedal <> 0.
4 = Signal enabled only after motor synchronization (one rotation at
positioning speed after power On).
5 = Motor runs Eco with setting F-84 and F-85
6 = Motor runs the same as chain suction at the seam start / end
with counter F-084 and F-085
7 = The same as 6, however chain suction at the start of the seam
can be interrupted and with switch-off delay F-156
7
0
1
156
t05 Switch-
off delay for the signal “run” or signal with pedal in
pos. 0 (neutral)
ms
2550
0
0
161
drE Direction of motor rotation
0 = Clockwise rotation
1 = Counterclockwise rotation
1
0
1
170
Sr1
-
See Section
Fehler! Verweisquelle konnte nicht
gefunden werden.
Setting the reference position
(Parameter 170)
172
Sr3 See Section 6.10 Indication of the setting of the positions
173
Sr4
See Section 8 Signal test
OFF
176
Sr6 Service routine for total operating hours display.
The process is as with display example of parameter 177.
177
Sr7 Service routine for display of hours since the last service.
Display example for the operator control panel:
Press the E key
Display
Sr7=
Press the >> key
Display
h t
Press the E key
Display
0000
Press the >> key
Display
h h
Press the E key
Display
0000
Press the E key
Display
Min
Press the E key
Display
00
Press the E key
Display
SEc
Press the E key
Display
00
Press the E key
Display
MS
Press the E key
Display
000
Press the E key
Display
rES
Press the E key again to restart routine, or press the P key twice to
return to operational status
179
Sr5 Display of control program number with index and more identification
numbers. The data is displayed in sequence by keystroke.
Display example for the operator control panel:
Press the E key
Display
Sr5=
Press the >> key
Display e.g.
5030
(Prog. No.)
Press the E key
Display e.g.
A
(Index)
Press the E key
Display e.g.
06
(Year)
Press the E key
Display e.g.
10
(Month)
Press the E key
Display e.g.
24
(Day)
Press the E key
Display e.g.
16
(Hour)
Press the E key
Display e.g.
--
Press the E key
Display e.g.
----
Press the E key again to restart routine, or press the P key twice to
return to operational status
Содержание AB600A5015
Страница 5: ... AB AB600A5015 Instruction Manual 5 ...
Страница 60: ......
Страница 61: ...Instruction Manual with parameter List Distribution For your notes ...
Страница 62: ... Parameter list 94 For your notes ...
Страница 63: ... AB620A5030 5032 Parameter list 95 For your notes ...