P/N: 61000-0011 REV: 4.0 Page 3 of 6
JUMPER SETTINGS
Table 1: FCOM card requirements and jumper settings
Outgoing format
RS-232
RS-485
20 mA loop
Fiber optic
Incoming format
RS-232
RS-485
20 mA loop
Fiber optic
P1: FCOM-232
P2: None
Code: 000001
P1: FCOM-485
P2: FCOM-232
P2: FCOM-485
P2: FCOM-20
P2: FCOM-FIB
Code: 111010
Code: 111111
Code: 111011
Code: 111011
P1: FCOM-20
P2: FCOM-232
P2: FCOM-485
P2: None
P2: FCOM-FIB
Code: 110010
Code: 110111
Code: 000011
Code: 110011
P1: FCOM-FIB
P2: FCOM-232
P2: FCOM-485
P2: FCOM-20
P2: None
Code: 110010
Code: 110111
Code: 110011
Code: 000011
P1: FCOM-232
P1: FCOM-232
P1: FCOM-232
P2: FCOM-485
P2: FCOM-20
P2: FCOM-FIB
Code: 110101
Code: 110001
Code: 110001
P1: FCOM-485
P1: FCOM-485
P1: FCOM-485
P1: FCOM-20
P1: FCOM-20
P1: FCOM-20
P1: FCOM-FIB
P1: FCOM-FIB
P1: FCOM-FIB
1
J6
1
J5
0
J4
1
J3
0
J2
1
J1
0 (Off)
1 (On)
Install JP1 and JP2 on FCOM-485 cards.
Install JP1 and JP2 on FCOM-FIB cards in
position 2/3.
1.
Notes
2.
The example above shows the configuration of a
printer that receives an RS-232 format signal and re-
transmits an RS-485 formatted signal (address
110101). For more information on choosing FCOM
card placement and jumper settings, see the
Application Flowchart.
FCOM JUMPERS
P5
LD1
LD2
P3
P4
RESET
S102
FCOM card
(incoming communications)
FCOM card
(outgoing communications)
COM
24V
P2
P1
U10
Paper
Take Up
switch
Paper
Advance
switch
SWITCH SETUP
Table 2: Printer function selection switches
Switch
Position
Function
U10-1
Off*
3.1 mm character height
On
2.2 mm character height
U10-2
Off*
Handstand characters
On
Normal character print
U10-3
U10-4
U10-5
Off*
Normal
On
Pulse width adjust on (factory use)
U10-6
Off*
Even parity (future use)
On
Odd parity (future use)
U10-7
Off*
1 stop bits (future use)
On
2 stop bits (future use)
*Factory default
See Table 2.
See Table 2.
Table 3: Baud rate selection switches
Switch
1200
2400
4800
9600
U10-3
Off
Off*
On
On
U10-4
Off
On*
Off
On
*Factory default
Ribbon cable
to printer mechanism
Black stripe
Red stripe
Ribbon cable
to printer cradle
From a dedicated power supply output
To paper take up reel
INTERNAL WIRING
Red wire
Black wire
Warning!
Disconnect power to cabinets before installing or
removing components. Failure to do so may result
in serious injury or loss of life.
!
!
Caution!
Notes
Observe static-sensitive material handling
practices.
See Jumper settings in Table 1.
See Switch setup in Tables 2 and 3.
1
1
2
2
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com
Содержание EST2
Страница 18: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 22: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 24: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 28: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 58: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 64: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 66: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 80: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 88: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 90: ...Technical Manuals Online http www tech man com firealarmresources com ...
Страница 92: ...Technical Manuals Online http www tech man com firealarmresources com ...