Page 52
Solution-8 Installation Manual
ISSUE401.DOC
Electronics Design & Manufacturing
Serial Printer Cable (CC809)
The serial interface cable has been designed to connect the
Solution-8
control panel to a serial 600 baud
printer. The connecting plug is suitable for connection to a TP-10 serial printer as used for the Digitalarm-908
series.
When connecting, one end of the cable connects to the
Solution-8
printed circuit board at the Modem
socket and the other end to your respective printer.
Once connected you can order a hard copy print out of all your programmed information by entering your
installer code followed by '1' + Away.
Use this feature to keep hard copy records of your control panels programmed data.
Solution
Programmer (CC814)
This programmer can be used to program the locations in a
Solution-8
control panel. It comes complete
with a one metre connecting cable and a socket for an external program key. The unit also has an built in
Programming Key which will reduce your programming time by storing your standard system configuration.
EDMSTU (CS800)
The EDMSTU (Securitel Interface) has been designed to operate in conjunction with the
Solution
range of
control panels using a serial connection. This means that all alarm information can be transmitted from the panel
to the STU using only 3 wires.
V3
The EDMSTU provides full serial reporting of alarms, opening and closing reports, isolations and user ID
information. Line integrity is also monitored by the monitoring control room.
Solution
System Programming Key
(CC810)
This is another first for the security industry designed by Electronics Design and Manufacturing. The
Programming Key is a unique device that holds all your control panel default configuration data. The
Programming Key can hold all your common configuration data such as monitoring station telephone numbers
and zone reporting channels for example. When used to program your control panel more than 90% of all
programming can be accomplished in five seconds. All that you are required to do is adjust the client number or
whatever data is unique to the particular installation. If you are a contractor working for multiple monitoring
stations then have several Programming Keys each one programmed uniquely for each particular monitoring
station. This will save you time and reduce the possibility of programming errors. As you can see the
Programming Key is a very useful device.
Solution
Modem Module (CC811)
This inexpensive module when fitted and selected via the appropriate programming option will allow you to
control, monitor and program your control panel remotely via the telephone network. This module will prove to
be a valuable asset when servicing systems located in remote, inaccessible sites. You can change the entry time,
user codes etc for your customer without even leaving your office. This feature will pay for itself in no time and
will assist you in taking your quality of service one step higher than your opposition. To make use of this feature
you will need to be familiar with the Alarm Link computer software.
Connection
Ensure that all power is disconnected from the
Solution-8
control panel. Locate the MODEM marking on
the printed circuit board. This can be found in the top right hand corner. There are eight pins which connect the
main printed circuit board to your modem module. Ensure that the orientation of the triangular markings on the
printed circuit board correspond to those on the modem. It is very important that this module is connected
correctly for proper operation.