Solution-8 Installation Manual
Page 11
Electronics Design & Manufacturing
ISSUE401.DOC
Via the Programming Key
The
Solution
Programming Key is a unique device that will allow you to easily program your control panel.
Inserting the Programming Key will automatically initiate a data transfer from the Programming Key to the
control panel memory.
If you have a new Programming Key you should first enter the Installers Program mode, configure your system as
per your requirements then insert the Programming Key while still in the Program mode and enter command 262.
This will copy the system data onto your new Programming Key. Exit the program mode by entering command
260, wait two seconds for the activity L.E.D. to return to its normal blinking state and then remove the
Programming Key. This Key will now become your standard data pattern for future programming of your
systems.
It should be noted that when entering the Installers Program Mode, inserting a Programming Key and then
altering any location will cause a simultaneous update of not only the Keys data but also the control panels data.
Therefore, you are not able to alter data in the Programming Key without the same location being altered in the
control panels memory.
Programming Option Bits
When programming these locations you will notice that there are four alternatives per location. You may select
one, two, three or all of these alternatives for each location, however only one number needs to be programmed.
This number is calculated by adding the option bit numbers together.
Example:
If at location 215 you want options 1, 2 and 4 then simply add the numbers together and the total is the number to
be programmed. In the example the number to be programmed is '7' (1+2+4=7)
Option Bit
Description
1
Forced arming to be allowed
2
Console panic to be audible
4
Invalid code tamper to be audible
8
Extinguish mode
Program Commands
V3
There are several commands that can be invoked to perform the functions as listed below. These commands only
operate whilst you are in the Installers Program mode. To invoke the command enter the commands numerical
code then press the AWAY key, three beeps will be heard and the command will be executed.
NOTE:
These commands do not operate when using Alarm link.
Command
Function
257
Random Select User Codes
258
Enable and Disable Zone status mode
259
Test key
260
Exit program mode
261
Set back to factory default
262
Copy the panel memory to the key
263
Copy the key data to the panel memory
264
Wipe key
265
Domestic Dialling Setup
266
Enable and Disable automatic stepping of locations during programming