
Solution-8 Installation Manual
Page 39
Electronics Design & Manufacturing
ISSUE401.DOC
Entry timer 1
Locations 228 - 229
0
Location 228 holds the 1 second increments and location 229 holds the 16 second increments. Therefore if you
want an entry time of 60 seconds then store a 12 into location 228 and a 3 into location 229.
Location
Description
228
Entry time in 1 second increments
229
Entry time in 16 second increments
Entry timer 2
Locations 230 - 231
41
Location 230 holds the 1 second increments and location 231 holds the 16 second increments. Therefore if you
want an entry time of 60 seconds then store a 12 into location 230 and a 3 in location 231.
Location
Description
230
Entry time in 1 second increments
231
Entry time in 16 second increments
Output 1
Locations 232 - 235
0000
Outputs consists of three items. The first is the event type being the conditions required to trigger the output.
Secondly a configuration option which determines the polarity and operation of the output once the conditions
are met. Lastly a time factor which determines the duration of the output. You will find that there are a large
number of event types to choose from and the flexibility of the output stage will enable you to control or do
almost anything you may require. See the output configurations chapter for more detail. Output 1 configuration
parameters are entered in these four locations.
Location
Description
232
Event type
233
Event polarity
234
Time in 200ms intervals
235
Time in 3.2 second intervals second intervals
Output 2
Locations 236 - 239
1100
Output 2 configuration parameters are entered in these four locations.
Location
Description
236
Event type
237
Event polarity
238
Time in 200ms intervals
239
Time in 3.2 second intervals second intervals