Solution-8 Installation Manual
Page 47
Electronics Design & Manufacturing
ISSUE401.DOC
Special Code Functions
Special function codes have been incorporated to allow temporary staff or non-code holder users to initiate
different functions as required.
SPECIAL CODE 9999
+
FUNCTION
+
AWAY
Code
Description
0
Not Used
1
Not Used
2
Not Used
3
Not Used
4
Not Used
5
Not Used
6
Initiate a Modem Call
7
Toggle Day Alarm
8
Not Used
9
Send a Test Report
6. Initiate a Modem Call
This mode will force the panel to call the telephone number programmed in locations 32 to 47 and attempt to
connect to the upload/download computer.
V3
7. Toggle Day Alarm
This code has been added to allow users who do not have access to the master code to activate and disable day
alarm. Because Day Alarm is now deactivated when exiting the Installers programming mode this code should be
fused to reactivate the mode when required.
9. Initiate a Test Report
By keying in the Special code followed by 9 then AWAY a test report will be immediately sent. This is handy if