Event Type Description
Type 0-EDMSAT
(On Output 1 only)
This output controls all functions of an EDM satellite siren.
V3
Type
0-EDMSTU
(On Output 2 only)
This output type has been added to allow for serial connection to the EDMSTU Securitel Unit.
This serial link, plus 13.8v and GND is all that is required to communicate to the EDMSTU.
The Hard ID number is programmed in the Client ID locations 52-55.
V3
Type 0-Day Alarm
(On Output 3 only)
This output type has been added to provide a separate Day alarm output for jobs where having
Entry Warning and Day alarm on the same output is not desired.
V3
Type 0-Entry Warning
(On Output 4 only)
This output type has been added to provide a separate Entry Warning output for jobs where
having Entry Warning and Day alarm on the same output is not desired.
V3
Type 0-Entry Warning
(On Console Buzzer only)
This output type has been added to allow you to use the console buzzer as the Entry Warning
sounder and to use Output 3 to drive a Day Alarm sounder.
Type 1-System Armed
This output activates as soon as the panel becomes armed (during and after exit time). It will reset when the panel
is next disarmed.
Type 2-System Stay
This event triggers as soon as the panel is armed in the Stay mode. It will reset when the panel is next disarmed.
Type 3-Exit with all Zones Sealed or Entry Warning.
This event type has dual functions. It will activate during exit time when all eight zones are sealed. The next time
it will activate will be during entry time.
Type 4-Exit Warning
Activates during exit time only. Zones can be sealed or unsealed.
Type 5-Entry Warning or Day Alarm
This feature will cause the output to trigger for Day alarm when the panel is disarmed. It will also trigger for
entry warning when the panel is being disarmed during the entry period. Day alarm zones need to be selected in
location 227.
Type 6-All Signals Transmitted Ok (Kiss Off)
This feature will cause the output to activate once the control panel has successfully transmitted all of its stored
alarm data.
Type 7-Silent Alarm
Activates whenever any silent alarm is triggered, whether the system is armed or disarmed. It will reset the next
time the system changes state.
Type 8-Auxiliary Output Code 1
This event is only functional while the system is in the disarmed state. Locations 152 to 157 defines where this
code is programmed. This output can be used to operate an electric door strike.