Optional Controller
eMI Wired control
EMI offers wired wall control compatible with EMI split sys-
tem air handlers for variable speed condensers.
fan Operation
Controls call for fan operation (On or Off).
After controller has been satisfied and call for heating or
cooling has been removed, indoor fan remains on for ad-
ditional 60 seconds. This increases efficiency by pulling
remaining energy from unit.
Indoor unit utilizes 3 speed motor. Fan speed selection is
made through fan button for wired controller Operation
(High, Med, Low).
Cooling Operation
Wired wall controls call for cooling operation (On or Off).
Place system switch in Cool mode after connecting
controller to unit.
• Adjust set-point temperature below room temperature.
• Compressor and fan motors start and cooling begins.
Place set-point temperature above room temperature.
• Outdoor condenser stops.
• Fan will operates as described in FAN operation.
Compressor has two (2) minute minimum run and three (3)
minute minimum “OFF”.
nOTICe
Once cooling has cycled off or following power
outage, compressor will not start for at least three
(3) minutes (short-cycle protection).
OPTIOnAl WIReD WAll COnTROlleR