EcoWave Package Overview
The EcoSmart Energy Management System
The EcoSmart Energy Management System reduces HVAC energy consumption without interfering with occupant
comfort.
EcoSmart thermostats such as the EcoTouch automatically learn and adapt to the heating and cooling patterns
of each room. For example, a room on the east side of a building will receive direct sunlight in the morning and
will either need less HVAC heating or more HVAC cooling. However, as the day progresses, the room will need
more HVAC heating or less HVAC cooling as it moves into the shade. An EcoSmart thermostat will continually
monitor the room, learn its patterns, and adjust its heating and cooling profiles accordingly.
EcoSmart thermostats also learn and adapt to occupant schedules. When a room is unoccupied, the EcoTouch
will enter an energy saving mode, allowing the room to drift away from the desired set point. During this drift
period, the thermostat will operate the HVAC unit less often, reducing energy costs. When the room becomes
occupied again, the RecoveryTime™ technology built into each EcoTouch will return the room to the set point
without occupant interaction.
The EcoWave is available in several configurations to address specific requirements of multiple applications
including hotel, classroom, office, university dormitory, military residence hall, retail, public area, convention
center, and a wide variety of commercial and industrial spaces.
The firmware of standalone EcoWave thermostats is identical to the firmware of networked versions.
Standalone Thermostats can be networked by adding a network module to the base units at any time.
Programming features used during installation, maintenance, and troubleshooting are available in the on-
screen Maintenance Menu.
Regulatory Compliance
FCC ID: XV6SS6560
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a class B digital device pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If the equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and the receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•
Consult the dealer or experienced radio/TV technician for help.
EcoWave Featur ing EcoTouch IO&M Guide
Telkonet, Inc.
For Use w ith Fir mw ar e Ver sion 2.x
20800 Sw enson Dr ive, Suite 175
Waukesha, WI 53186
Revision 2
(800) 380-9640
Page 2