SHENZHEN ECON TECHNOLOGY CO.,LTD User Manual For
EHS-580 EtherCAT Hybrid Servo Drive
2154+00
Logic configuration for
inputs
R/W/S
0
0/1
0
:
Positive logic
1
:
negative logic
bit0: input1 polarity setting
bit1: input2 polarity setting
bit2: input3 polarity setting
bit3: input4 polarity setting
bit4: input5 polarity setting
2155+00
Level configuration for
inputs
R
0
0/1
0
:
Low level
1
:
High level
bit0: input1 polarity setting
bit1: input2 polarity setting
bit2: input3 polarity setting
bit3: input4 polarity setting
bit4: input5 polarity setting
IO Status display
Address
Definition
Description
60FD+00
Input status
R
bit0
:
limit-
bit1
:
limit+
bit2
:
homing
3.2
Output configuration
A:
The power supply for outputs is 12-24VDC, and if power supply is wrong wiring, it is a risk to burnt the drive
B: It is OC output with the maximum capacity of 50mA/25V, it is recommended to connect a resistor to power
supply(1K Ohm for 12VDC ,2K Ohm for 24VDC)
C:
If the output is a relay, it is recommended to connect a freewheel diode with inverse parallel connection to relay
for protection the drive
Address
Definition
Default value
Range
Descriptio
n
2005+01
Output1
R/W/S
1
1—4
bit0
:
Alarm output
bit1
:
Ready output
Bit2: Pend output
2005+02
Output 2
R/W/S
1
1—4
bit0
:
Alarm output
bit1
:
Ready output
Bit2: Pend output