SHENZHEN ECON TECHNOLOGY CO.,LTD User Manual For
EHS-580 EtherCAT Hybrid Servo Drive
RXPDO4
(1603h)
01h
60400010h
6040h
00h
10h (16bits)
Control word
02h
60980008h
6098h
00h
08h (8bits)
Homing mode
03h
60990120h
6099h
01h
20h (32bits)
Homing speed (fast)
04h
60990220h
6099h
02h
20h (32bits)
Homing speed(slow)
05h
609A0020h
609Ah
00h
20h (32bits)
Homing
acceleration/
deceleration
06h
607C0020h
607Ch
00h
20h (32bits)
Homing offset
07h
60600008h
6060h
00h
08h (8bits)
Operation mode
TXPDO1
(1A00h)
01h
603F0020h
603Fh
00h
10h (16bits)
Latest errorcode
02h
60410010h
6041h
00h
10h (16bits)
Status word
03h
60610008h
6061h
00h
08h (8bits)
Operation mode
display
04h
60640020h
6064h
00h
20h (32bits)
Actual position
05h
60B90008h
60B9h
00h
10h (16bits)
Probe status
06h
60BA0020h
60BAh
00h
20h (32bits)
Probe 1 rising edge
position
07h
60FD0020h
60FDh
00h
20h (32bits)
Digital input status
TXPDO2
(1A01h)
No default mapping
5.4.2 PDO dynamical mapping
COE use PDO specified object(1C12h/1C13h) to configure PDO mapping object(1600h~1603h/1A00h~1A01h) to
the PDO object synchronization manager (synchronization manager 2/3)
PDO specified object
Index
Sub-index
Range
Data type
Access property
RXPDO
Specified
object (1C12h)
00h
0~4
U8
*1)
RO
01h
1600h~1603h
U16
RW
02h
U16
RW
03h
U16
RW
04h
U16
RW
TXPDO
Specified
object (1C13h)
00h
0~2
U8
RO
01h
1A00h~1A01h
U16
RW
02h
U16
RW
5.4.3The difference of PDO and SDO
Contrast terms
PDO
SDO