SHENZHEN ECON TECHNOLOGY CO.,LTD User Manual For
EHS-580 EtherCAT Hybrid Servo Drive
RXPDO
6040h
Control word
User self-defined
-
607Ah
Target Position
User self-defined
Unit
60B0h
Maximum speed
User self-defined
Unit/s
2000h
Revolution per round
User self-defined
pulse
TXPDO
6041h
Status word
Read only
-
6064h
Actually position Feedback
Read only
Unit
606Ch
Actual velocity feedback
Read only
Unit/s
603Fh
Error code
Read only
-
6061h
Operation mode display
Read only
-
2.4 Homing mode(HM)
Homing mode is the way of detecting the home point with command of Control word (6040h). 6060h is address for
homing Mode enable/disable. And will execute the command once Mode of operation display (6061h) indicates
Homing Mode.
2.4.1 Related objects
Data write/read
Object
Description
Value
Unit
RXPDO
6060h
Operation Mode
1
-
6040h
Control word
User self-defined
-
607Ah
Target Position
User self-defined
Unit
6081h
Maximum speed
User self-defined
Unit/s
6082h
Start /Stop speed
User self-defined
Unit/S^2
6083h
Profile Acceleration
User self-defined
Unit/S^2
6084h
Profile Deceleration
User self-defined
Unit/S^2
6085h
Emergency stop deceleration, base
on the value of 605Ah
User self-defined
Unit/S^2
605Ah
Enable the deceleration of E-stop(5:
enable; Others: disable)
User self-defined
-
2000h
Revolution per round
User self-defined
pulse
TXPDO
6041h
Status word
Read only
-
6064h
Actually position Feedback
Read only
Unit
606Ch
Actual velocity feedback
Read only
Unit/s
603Fh
Error code
Read only
-
6061h
Operation mode display
Read only
-
2.4.2 The bits 4~6 of Control word (6040h)