4. Combustion Measurement
4.1 Prepare Combustion Measurement
Prepare instrument for measurement operation by making all con-
nections (T-Room sensor and T-Gas, GAS and DRA of the 3-
chamber hose). Make sure that:
-the condensate pad has sufficient capacity
-the condensate pad is not soiled darker than no. 3 on the soot scale
4.2. Gas Analysis
Once the calibration cycle is over, the instrument enters the meas-
urement mode. The measurement values could be displayed on 4
screen pages (3 x gas analysis; 1 x draught measurement – change
with curser keys):
Just position the probe in the exhaust pipe once the
calibration phase is over!
To obtain accurate measurement values it’s
important to re-calibrate the instrument after each
measurement (at the latest after one hour)!
O2
4.0
%
CO2
12.5
%
CO
30
ppm
Lambda
1.23
T.Gas
166
°C
T.Air
20
°C
Losses
7.0
%
Eta
93.0
%
O2
4.0
%
CO2
12.5
%
T.Air
20
°C
T.Gas
212
°C
O2
4.0
%
CO2
12.5
%
CO
30
ppm
Lambda
1.23
Condensate pad