ecom-B
Page 19
6.2. Fan burners
Select from the main menu the sub menu
“Fan burner”
and press
<Enter>
. The table of fuel types will be displayed. Following fuel
types can be selected:
Natural gas (B)
Town gas (B)
Coke gas (B)
Liquid gas (B)
Select with the arrow keys the correspond-
ing fuel type and confirm by pressing
<En-
ter>
.
6.2.1. Gas fan burners
Selecting a gas fuel type the routine starts
with the measurement
“Connecting pres-
sure”
. To operate the measurement (0 –
100 hPa) the draught hose must be con-
nected. In case of deviations of the zero
point it could be reset by pressing
<CAL>
.
Connect the draught hose with the instru-
ment. After the pressure has stabilised it
can be stored by pressing
<store>
for later
printout. By pressing the key
<store>
again
the value will be deleted. Using the cursor
<down>
it could be get to the next meas-
urement.
Operate the following pressure measure-
ment as described above. Not needed
measurements can be skipped by using
the cursor key
<down>
(these will not be
printed).
Type of fuel
Natural gas (B)
CO2max : 11.8
A1-fact. : 0.37
Select with
↑↓
Burn. w. blower
Connection pressure
22.1
hPa
Val.:
22.1
hPa
Set zero point
CAL.
Burn. w. blower
Nozzle pres fu. load
13.0
hPa
Val.:
13.0
hPa
Set zero point
CAL.
Burn. w. blower
Nozzle pres pa. load
6.4
hPa
Val.:
6.4
hPa
Set zero point
CAL.
Burn. w. blower
Flow pressure
18.7
hPa
Val.:
18.7
hPa
Set zero point
CAL.