Page 28
ecom-B
Pressure Test
The
“Pressure Test”
up to 100 hPa is deposited as a measurement
routine in the ecom-B. Proceed as follows:
1. Close the conduit with a suitable adapter (test stopple, high-
pressure stopple or one-pipe counter cap).
2. Connect the components as described before.
3. Scroll with cursor keys
<Up/Down>
to the menu
“Pressure Test”
.
Activate with
<Enter>
.
4. Create the pre-adjusted test pressure (max. 100 hPa) with the air
pump.
5. Interrupt the connection to the air pump (switch-off the ball valve)
and start
“Pressure Test”
with
<Enter>
.
6. Wait for stabilization time (the measurement will start automatical-
ly).
7. Once the measurement time is over, the result is displayed and
can be printed (IR printer required) by pressing
<Print>
.
8. If the menu
“Pressure Test”
is selected again, so the result can
be called up with
“No” / <Enter>
(as long as the ecom-B is on) or a
new measurement can be started with
“Yes” / <Enter>
(switching
from
“No“
to
“Yes“
with cursor keys
<Up/Down>
).
Содержание B