12. Technical Data
Parameter
Range
Measurement principles
O
2
0 ... 21 vol.%
electrochemical
CO (without H
2
)
0 ... 2000 ppm
electrochemical
CO (with H
2
-option) 0 ...4000 ppm
electrochemical
NO (Option)
0 ...5000 ppm
electrochemical
CO
2
0 ...CO
2max
calculated
T-G
0 ... 500 °C
NiCr-Ni
T-R
0 ... 100 °C
semiconductor
Pressure
0 ... +/- 100 hPa
DMS-bridge
Efficiency
0 ... 120 %
calculated
Losses
0 ... 99,9 %
calculated
Lambda
1 ...
∞
calculated
CO-undiluted (reference-O
2
; adjustable)
calculated
Dew point of combustion gases
calculated
Power Supply
110 - 230 V~ / 50 - 60 Hz;
Battery
6 V / 3,3 Ah
Display:
graphic display, backlit
Size
(W x H x D) 250 mm x 180 mm x 80 mm
Weight
approx. 2,1 kg (complete with sampling system)
Application limits
+5 °C to +40 °C;
max. 90 % RH, non-condensing