63
Set
tings
•
Post/pre fader control
.
o
If the post fader is
enabled, the signal is sent
to the output
after processing and after the
fader for the selected input signal.
•
If the post fader control is
disabled, the signal
is sent to the output after processing or
after
wards (selectable by the post DSP control)
and prior to the fader for the selected input
signal.
•
Status LEDs
:
o
STBY / MUTE
: shows the standby status of the
output (if amplified) and whether it is affected
by any group or external MUTE. Exclusive for
amplified outputs.
o
LGRP
: local group indicator. If lit, it means that
the output belongs to at least one local group.
Clicking on the indicator brings up the list of
groups to which the output belongs; the list
can be edited quickly from there.
o
NGRP:
Network Group Indicator. If lit, the output
belongs to at least one network group. Clicking
on the indicator brings up the list of groups to
which the output belongs; the list can be edited
quickly from there.
•
Volume control
for the output and VU meter.
•
MUTE button
, to mute the output.