Set
tings
4.9
GPO PORTS
VIDA has on its
rear panel 4, relay outputs NO / NC (normally open / normally closed)
.
Each of these outputs can have its status change associated with a user preset by means
of a specific function programmed through VIDA web application, such as a calendar event
or the touch of a key available on a user panel. In this way, it is possible to interact with
external equipment, such as motors for projection screens or movable partition walls,
lights, sirens, GPI inputs from other equipment, etc.
4.10
EXTERNAL MUTE
VIDA has on its
rear panel
a
control input, or EXT. MUTE port (Normally Open = MUTE
OFF / Closed = MUTE ON)
, which allows the activation /deactivation of the mute of audio
outputs (zones) of the unit by means of a push button, relay or external potential free
contact closure.
•
The assignment of
outputs affected by the MUTE port is configured from VIDA
web application
.
•
Please
refer to the VIDA web application manual