A. Water Heater Location
Installed indoors.
Close to area of mostly used outlet.
Protected from freezing temperatures.
Proper clearance from combustible surfaces observed.
Provisions made to protect area from water damage.
Combustible materials, such as clothing, cleaning materials, rags, etc. clear of the heater and
vent piping.
Water heater is properly attached to the wall.
B. Water Supply
Air purged from water heater and piping.
Water connections tight and free of leaks.
Materials used are as instructed in this manual.
Water pipes are insulated.
C. Gas Supply
Gas type matches data plate.
Approved pipe joint compound used.
for any possible gas leak.
Gas Company inspected installation (if required).
D. Relief Valve
Pressure Relief Valve properly installed and discharge line run to open drain.
Discharge line protected from freezing.
E . Electrical Wiring
Voltage matches data plate.
Water heater is properly grounded.
Wiring meets all local codes.
GFCI Protection where required.
Installation Checklist