PLEASE NOTE: SH12 IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT
NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR THE MOST UP TO DATE WARRANTY AND MANUAL.
• The venting pipe must have 7cm of clearance in every direction from the
point that it passes through a wall.
• The location of the opening in the wall should be protected from
• The location of the venting pipe outlet and the surrounding non-
combustible building materials shall meet the requirements as shown in
• There should be no other intake or exhaust vents within 60cm of the
exhaust pipe outlet.
• The vent pipe must use the termination elbow with screen included in
the ventilation kit to protect the water heater, exhaust system, building
in which the water heater is installed, and persons located near the water
heater and venting system.
•
• Water heater exhaust gasses must not be routed through interior living
spaces such as from a closet through a kitchen. The water heater must be
installed on an interior wall that can directly vent exhaust gases outdoors
via the ventilation kit.
• The water heater must not vent exhaust gases into closed building
corridors, onto balconies, through windows, etc.