supply
pressure. DO NOT use an industrial type gas regulator.
The water heater and its gas connections must be leak tested at normal operating pressures before it is placed in
operation.
•
•
Bubbles indicate a gas leak that must be corrected.
•
All connections should also be leak tested after the water heater is placed in operation.
any pressure testing of the gas supply piping at pressures equal to or less than 1/2 psi (14”w.c.).
The Eccotemp
SMART
HOME SH12 Gas Tankless Water Heater has been tested for use at elevations up to 2000
ft.(609m). Installation and use of the Eccotemp
SMART
SMART
HOME SH12 above 5000
ft.(1524m) is not recommended.
A new pressure relief valve, that complies with your local municipality's codes, must be installed at the hot
water outlet connection of the water heater at the time of installation. Local codes shall govern the installation
of relief valves. Pressure relief valves are not included with your water heater but are available for purchase at
eu.eccotemp.com
For safe operation of the water heater, be sure that:
•
1034 kPa)
the water heater as marked on the data plate.
•
plate.
•
•
Discharge from the relief valve should be piped to a suitable drain to eliminate potential water damage. Piping
used should be of a type approved for the distribution of hot water.
•
Hot and cold water lines should be insulated up to the water heater.
•
complete drainage (by gravity) of the relief valve and discharge line.
•
valve of any type, restriction or reducer coupling should be installed in discharge line.
NOTICE: The diagram below illustrates a pressure relief valve. If local codes require a combination temperature
NOTICE:
Local codes govern the installation of relief valves. If local
codes require that a temperature and pressure relief valve should
be installed the manufacturer recommends a type 40XL Watts T&P
relief valve or an equivalent model be used.
NOTICE:
Manual operation of relief valves should be performed
manual operation of the relief valve. You should take precaution to
avoid contact with the hot water coming out of the relief valve and
to prevent water damage.
NOTICE:
If the relief valve on the system discharges periodically,
system. Contact the water supplier or local plumbing inspector
on how to correct this situation. Do not plug the relief valve.
Relief Valve
Leak Testing
High Altitude
(15.2cm)
Pressure Testing the Gas Supply System
1/2" BSPP(G)
1/2" BSPP(G)
(1.27cm)
(1.27cm)