MAINTENANCE
STEP 6 – OIL FILTER
Dismantle the used oil filter by an oil filter spanner.
Used filters must be disposed in accordance with the applicable country
regulations. Improper disposal of used filters represents a hazard to the
environment!
Take the new oil filter, put a little oil onto the rubber seal and tighten the oil
filter manually.
Do not use any tools to fit the oil filter as they could damage it!
STEP 7 – PLUG FOR MEASURING POINT
Depending on the type of exhaust gas pipe, consider replacing the plug in
the exhaust gas opening on the exhaust gas pipe upstream of the Power
Unit.
STEP 8 – LAMBDA SENSOR
Separate the lambda sensor cable from the cable tree at the plug-in contact.
Unscrew the old lambda sensor from its socket by a lambda sensor top long
and screw in the new lambda sensor.
Reconnect the Lambda sensor cable to the cable tree.
STEP 9 – NEW SPARK PLUGS
The temperatures of the spark plugs and the cylinder head have now equalised.
Fasten the new spark plugs by a torque wrench with a
16 mm
spark plug
insert and put the spark plug cap back on.
Torque:
18 Nm
.
Fig. 5.31
Fig. 5.32
Fig. 5.33
Fig. 5.34
Fig. 5.35
Fig. 5.36
23