www.eberg.eu
Mist is emitted
from indoor unit’s
air outlet.
Indoor temperature and humidity
is high?
Because indoor air is cooled rapidly.
After a while, indoor temperature and
humidity will be decrease and mist
will disappear.
Set temperature
can’t be adjusted
Unit is operating under auto
mode?
Temperature can’t be adjusted under
auto mode.
Please switch the operation mode if
you need to adjust temperature.
Your required temperature exceeds
the set temperature range?
Set temperature range: 16°C – 31°C.
Cooling (heating)
effect is not good.
Voltage is too low?
Wait until the voltage resumes
normal.
Filter is dirty?
Clean the filter.
Set temperature is in proper range?
Adjust temperature to proper range.
Door and window are open?
Close door and window.
No air emitted from
indoor unit.
Air inlet or air outlet of indoor unit is
blocked?
Eliminate obstacles.
Under heating mode, indoor tem-
perature is reached to set tempera-
ture?
After reaching to set temperature, in-
door unit will stop blowing out air.
Heating mode is turned on just
now?
In order to prevent blowing out
cold air, indoor unit will be started
after delaying for several minutes,
which is a normal phenomenon.
Air conditioner
can’t operate
Power failure?
Wait until power recovery.
Is plug loose?
Reinsert the plug.
Circuit break trips off or fuse is burnt
out?
Ask professional to replace circuit
break or fuse.
Wiring has malfunction?
Ask professional to replace it
Unit has restarted immediately after
stopping operation?
Wait for 3min, and then turn on the
unit again.
Whether the function setting for
remote controller is correct?
Reset the function.
Содержание AORI E25-09
Страница 69: ...eberg eu KARTA GWARANCYJNA URZA DZEŃ KLIMATYZACYJNYCH MARKI EBERG ...
Страница 74: ...Data przeglądu Pieczęć i podpis serwisu Uwagi adnotacje Przeglądy techniczne ...
Страница 75: ...Data naprawy Opis Pieczęć i podpis Punktu Serwisowego Naprawy ...
Страница 76: ...Climateo Sp z o o Kokotów 703 32 002 Kokotów biuro eberg eu tel 48 513 677 545 www eberg eu ...