11 Representation of the XNE-2CNT-2PWM in CANopen
11.1 Objects for counter modules
XI/ON: XNE-2CNT-2PWM
04/2011 MN05002035Z-EN
www.eaton.com
125
Object 5901hex – PWM Config
The object 5901
hex
affects the configuration parameters of PWMx:
Write accesses initiate a parameter update via the internal module bus of the XI/ON station.
The parameter is stored as a non-volatile parameter in the XI/ON gateway and is restored with
every node reset.
Structure of the data bytes
Table 40:
Object 5901
hex
Feature
Sub-index
Description
Name PWM
Config
Object code
ARRAY
PDO mapping
-
Data type
0×00
Unsigned 8
0×01
to 0×47
Unsigned 32
Access
0×00
ro
0×01
to 0×47
rw
Default value
0×00
-
0×01
to 0×47
-
Sub-index
0×00
≤
n
≥
0×47
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(lsb)
n
= PWM1
0
diagnostic
PWM1
X
mode D1
(0×3F)
1
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
DBP1 STS MODE
(0×00)
substitute
value P1
(0×00)
substitute
value D1
(0×00)
mode PWM1
(0×00)
2
Bit 23
Bit 22
Bit 21
Bit 20
Bit 19
Bit 18
Bit 17
Bit 16
X
3
Bit 31
(msb)
Bit 30
Bit 29
Bit 28
Bit 27
Bit 26
Bit 25
Bit 24
X
ADR AUX REG1 WR DATA (0×60)