HUA Response
This option controls the audible alarm associated with Hold-Up Alarms (HUAs).
Note:
All HUAs are disabled when an installer is using the Installer menu.
HUA Keys Active
(page 48) must be enabled to generate HUA alarms from
keypads.
Audible
The control unit starts HUA alarm tones from keypads and loudspeakers, operates
HUA outputs, and activates any sirens. The sirens follow the
Siren Time
(see page
46).
Silent
The control unit keeps the HUA alarm silent: there are no alarm tones, and any
sirens or HUA outputs remain inactive.
Displayed
All keypad displays show an HUA alert message immediately (a user does not have
to enter an access code to see the message). If more than one HUA is active, the
display scrolls through the alert messages at approximately one-second intervals.
The control unit also starts HUA alarm from keypads and loudspeakers, operates
HUA outputs, and activates any sirens.
HUA Confirm Time
This is available only when
Confirmation Mode
is set to BS8243. This option determines
the length of the confirmation time for confirmed HUAs.
If the confirmation time expires after an unconfirmed Hold-Up Alarm (HUA), and the Hold-
Up Device (HUD) is still active, the control unit omits the active device and communicates
“Omitted HUD” to the ARC. If the system is unset, the control unit displays an alert at the
appropriate keypads.
If you wish to generate a confirmed HUA for test purposes only, you can set the HUA
confirm time to 0.
Note:
The time must be between 8 and 20 hours to comply with BS8243:2010 5.4.1.2.
Tamper as Tamper Only
This is available only when
Confirmation Mode
is set to BS8243. The purpose of the option
is to ensure strict compliance with BS8243 when reporting tampers to ARCs.
Enabled
When an unconfirmed tamper occurs, the control unit sends only “Tamper” to the
ARC and activates any output configured as type Tamper (this follows Scantronic
’s
understanding that BS8243, Annex H.7.1 applies to all grades).
Disabled
When an unconfirmed Tamper occurs the control unit sends “Tamper”, “General
Fault” and “Burg” to the ARC. In addition it activates any outputs of type Tamper and
General Fault.
Note:
This option does not comply with BS8243.
The behaviour of the Disabled setting is used when
Confirmation Mode
is Basic or
DD243.