![Eaton Scantronic i-on10 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/eaton/scantronic-i-on10/scantronic-i-on10_configuration-manual_3911046054.webp)
System Options Menu
Page 54
1 zone
The control unit starts a confirmed alarm if the intruder activates one or more zones
(not on the entry route) after entering the premises through the final exit zone.
2 zones
The control unit starts a confirmed alarm if an intruder activates two or more zones
(not on the entry route) after entering the premises through the final exit zone (used
for DD243:2004 clauses 6.4.5)
Note:
This option is not available if you have selected
BS8243 for Confirmation Mode.
Entry Keypad Lock
This is available only when
Confirmation Mode
is set to DD243 or BS8243.
The option determines whether the user can unset the system by entering an access code
after opening the entry door. Select one of the following:
Off
The user can enter an access code at the keypad after the entry door opens (used
for DD243:2004 clause 6.4.4).
On
The user must unset the system by some means other than the keypad, such as a
proximity tag or key switch (used for DD243:2004 clause 6.4.5 and BS8243:2010
6.4.5b).
Note:
This option has no effect if the alarm response (for either full set or part set) is
set to Siren or Internal. In those cases, the user will still be able to unset the system
using an access code.
Entry Keypad Lock
is intended for use when the system can
summon a police response.
Sounder On
Unconfirm
When the system is set, keypads and loudspeakers give the alarm sound when an
unconfirmed alarm occurs.
Confirm
When the system is set, keypads and loudspeakers do not give the alarm sound until
a confirmed alarm occurs.
Note:
The control unit will not allow you to select
Sounder on
– Confirm
at the same
time as
Siren on
– Unconfirm
.
Sounder and siren operation
The behaviour of sounder and siren operation is described in Table 6.
Table 6: Sounder and Siren Operation
Settings
Effect
Sounder On
Siren On
Unconfirm
Unconfirm Unconfirmed alarm: keypads, loudspeakers and sirens
sound immediately and run for the
Siren Time
(see page
Confirmed alarm: the control unit restarts the alarm sound at
all devices, which runs for the full
Siren Time
, even if that
had expired earlier.