Setting Options Menu
Page 47
Final Exit
Any zones of type Final Exit with Part Set B, C or D attributes continue to act as Final
Exit zones during part setting.
Normal Alarm
Any zones of type Final Exit with the Part Set B, C or D attributes act as Normal
Alarm zones during part setting.
Pt.set Entry Route
Note:
This is available only for a part set. This option controls how the system treats Entry
Route zones when the system is part set.
Entry Route
Any zones of type Entry Route with the Part Set B, C or D attributes continue to act
as Entry Routes zones during part setting.
Final Exit
Any zones of type Entry Route zones with the Part Set B, C or D attributes act as
Final Exit zones during part setting.
Strobe on Set
When set to On, this option causes the control unit to activate any output of type Strobe,
and the strobe on any sirens. The outputs/strobes are active for ten seconds after the
system sets.
Strobe on Unset
When set to On, this option causes the control unit to activate any output of type Strobe,
and the strobe on any sirens. The outputs/strobes are active for ten seconds after the
system unsets.