Chapter 5: Outputs Menu
This chapter explains the options in the Outputs menu.
Wired Outputs
The Wired Outputs menu provides access to edit the configuration of the three hardwired
outputs on the control unit's PCB.
1.
Select
Panel
. The display shows the current configuration for output 1. The bottom
line of the display shows the output's output type (by default, "Siren").
2.
Select either output 1, 2 or 3.
You can edit the output's
Name
,
Type
and
Polarity
, as described next.
Name
Specifies the output's name.
Type
Select the output type:
Note:
You can select an output type quickly by entering the number shown in brackets
after the type’s name, for example:“04” to select Open/Close. The number does not
appear on the display.
Not Used (00)
The output is never active.
Fire Alarm (01)
Active when the control unit starts a fire alarm.
Hold Up Alarm (02)
Active when the control unit starts a hold up alarm.
Burglar Alarm (03)
Active when any of the following zones are triggered while set: Normal Alarm,
Tamper (in a set system), Entry Route, Tamper Zone (in a set system), Entry time
expires, 24 hour (in a set system).
Open/Close (04)
Active when the system is unset. Inactive when the system is set.
Note:
This output is inverted relative to other outputs, it is normally at 0V for an unset
(open) system.
Alarm Abort (05)
Active when an alarm has been aborted by the user within the abort period.
Deactivates when the alarm is reset.
Technical Alarm (06)
Active when there is a technical alarm. Deactivates when the zone causing the alarm
is restored AND a user enters a valid access code to acknowledge the technical
alarm alert.