Configuring the System − Getting Started
Page 19
6.
Choose the language:
From this point on, the display operates in the selected language. If you want to
change the language later, use
Installer menu
– System Options – Updates –
Language
.
7.
Choose the country version you want to use:
8.
Select the wiring type to use for wired zones:
Further information about zone wiring types is given on page 14.
Note:
If you are using an ADP-10CC board (to provide ten on-board 4-wire CC zones
instead of ten FSL zones), select 2-wire FSL 2k2/4k7 as the wiring type.
Note:
You can change this setting later using
Installer menu
– System Options
.
9.
If you selected the UK as the country version, specify the alarm confirmation mode:
Please refer to page 52 if you need information about confirmation modes. You can
change this setting later using
Installer menu
– System Options – Confirmation –
Confirmation Mode.
10. User codes (e.g. to set or unset the system) can be four or six digits long. Select the
required length:
Note:
You can change this setting later using Installer menu
– System Options
–
Restore Defaults
– Staged Defaults – Users
.
11. Specify an installer code:
When prompted, confirm the code.
DO NOT FORGET THIS CODE!
12. Specify a code for the default master user:
When prompted, confirm the code.
DO NOT FORGET THIS CODE!
13. You will see one of the following:
If the lid of the control unit is closed, you will see the standby screen. For
example:
You can change the wiring type by pressing
one or more
times. Press
to continue.
Press
if you want to select six-digit user codes. Press
to
continue. (The
Follow Panel Grade
option sets user codes to the
default length for the panel grade, which for i-on10 is four digits.)
Use the numeric keys to specify the code.
You can change the country by pressing
one or more times.
Press
to continue.
You can change the language by pressing
one or more times.
Press
to continue.
You can change the confirmation mode by pressing
one or more
times. Press
to continue.