Outputs Menu
Page 39
Confirmed Alarm (07)
Active when there is a confirmed alarm. Deactivates when the system is reset. The
operation of this output type depends on the option selected in
System Options
–
Confirmation
– Confirmation Mode
(see page 52):
A/C Fail (12)
Active when mains power is absent. The action of this output depends on the value
programmed in
System Options
– Hardware – Mains Fail Delay
(see page 57).
Battery Fault (13)
Active when the control unit detects a fault with its backup battery. The control unit
deactivates the output when it detects a good battery.
Tamper (16)
Active when the control unit detects a tamper at the control unit (lid or back), wired
keypad, detector, or when there is an activation of a zone of type Tamper.
The control unit deactivates the output when tamper is reset.
Zone Omit (Setting) (17)
Active when the user omits a zone while setting the system. The output deactivates
when the control unit restores the zone.
Zone Omit (System) (18)
In the event of an unconfirmed alarm,
the system will rearm itself when the
confirmation timer expires. If the zone that caused the unconfirmed alarm is still
active at the time of the rearm, the control unit will omit that zone and activate the
output. The control unit will restore the zone and output when a user or engineer
resets the system.
General Fault (19)
Active when there is any event that causes an alert indication. This includes: AC Fail,
Battery Fault and Tamper.
Note that a General Fault output will trigger within a few seconds of an AC Fail, and
is NOT affected by the
Mains Fail Delay
setting.
Siren (21)
Active when the control unit starts a full alarm, a hold up alarm or a fire alarm (the
siren has a distinctive tone during a fire alarm). The control unit deactivates this
output at the end of the siren time. See page 46 to choose the siren duration.
Strobe (22)
Active when either of the following occurs:
a) The control unit starts a full alarm, hold-up alarm or fire alarm. The output remains
active until the user disarms the system.
b) Setting or unsetting, if you have selected “strobe on set” and/or “strobe on unset”
(see page 46).
Entry Exit Follow (23)
Active when the entry or exit time starts and deactivates at the end of the entry/exit
time, or if the entry/exit time is terminated. The output can be used for a separate
entry/exit buzzer. Note that the output does not operate if the exit mode is silent set
or instant set.
Armed (24)
Active when the system is full or part set.