Generator Fail
Generator Control
is active but the SC200 has not detected that the ac supply is
present (rectifiers have not turned on) after the
Generator Fail Alarm Recognition
Period
.
High Float
The bus voltage is above its normal range (set by the
High Float Threshold
).
High Load
The bus voltage is higher than the safe range for the load and/or battery (set by the
High Load Threshold
).
In Discharge
Battery Charge State
is
Discharge
(see details on page
Load Fuse Fail
A load fuse has blown or a load disconnect device has operated (indicated by an
active digital input with
Function
"Load Fuse Fail").
Low Float
The bus voltage is below its normal range (set by the
Low Float Threshold
).
Low Load
The bus voltage is lower than the safe range for the load and/or battery (set by the
Low Load Threshold
).
LVD Characterization Error
An LVD contactor must be characterized. See Low Voltage Disconnect on page
LVD Disconnected
An LVD contactor has disconnected the battery or load. See Low Voltage Disconnect
on page
LVD Fail
An LVD contactor is faulty or the control cable from the I/O board is disconnected.
See Low Voltage Disconnect on page
LVD Manual
An LVD is set to MANUAL CONNECT or MANUAL DISCONNECT. See Low
Voltage Disconnect on page
Missing Hardware
The SC200 has lost communication with a mapped I/O board or SiteSure-3G
module. Or, an input or output is mapped to an invalid I/O board or SiteSure-3G
module. See I/O Board Mapping on page
MOV Fail
One or more MOV cartridges have failed and must be replaced (indicated by an
active digital input with
Function
set to "MOV Fail").
Multiple Rectifier
Comms Lost
More than one rectifier has lost communications. See also Rectifier Comms Lost on
page
Multiple Rectifier Fail
Multiple rectifiers are faulty or their ac supply has failed without causing partial or
total ac supply failure.
Inhibited by:
AC Fail
and
Partial AC Fail
(if no more than one rectifier has failed
while still detecting the AC supply). See details of Alarm Inhibiting on page
Partial AC Fail
A digital input with
Function
set to "Phase Fail" is active, or more than 20% of single-
phase rectifiers are reporting ac supply failure, or all 3-phase rectifiers are reporting
loss of the same phase.
Inhibited by:
AC Fail
. See details of Alarm Inhibiting on page
Rectifier Comms Lost
Normally this alarm indicates that a rectifier has been removed during routine
maintenance. However, faulty rectifier communications or losing the rectifier
communications bus can also trigger this alarm. If removing multiple rectifiers
triggers this alarm, reset it from the keypad before it triggers an external alarm.
Inhibited by:
Multiple Rectifier Comms Lost
. See details of Alarm Inhibiting on page
Rectifier Current Limit
Rectifier(s) in current limit.
Rectifier Fail
A rectifier is faulty or its ac supply has failed without causing partial or total ac
supply failure.
Inhibited by:
Multiple Rectifier Fail
,
AC Fail
and
Partial AC Fail
(if no rectifiers have
failed while still detecting the AC supply). See details of Alarm Inhibiting on page
Содержание SC200
Страница 4: ......
Страница 8: ......
Страница 28: ...SC200 Handbook 20 Copyright 2007 2011 Eaton Corporation All Rights Reserved IPN 997 00012 50H November 2011...
Страница 88: ...SC200 Handbook 80 Copyright 2007 2011 Eaton Corporation All Rights Reserved IPN 997 00012 50H November 2011...
Страница 116: ...SC200 Handbook 108 Copyright 2007 2011 Eaton Corporation All Rights Reserved IPN 997 00012 50H November 2011...
Страница 120: ...SC200 Handbook 112 Copyright 2007 2011 Eaton Corporation All Rights Reserved IPN 997 00012 50H November 2011...
Страница 130: ...SC200 Handbook 122 Copyright 2007 2011 Eaton Corporation All Rights Reserved IPN 997 00012 50H November 2011...
Страница 134: ...SC200 Handbook 126 Copyright 2007 2011 Eaton Corporation All Rights Reserved IPN 997 00012 50H November 2011...