69
Powerware
®
Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA)
Uncontrolled Copy
C H A P T E R
6
S
PECIFICATIONS
Prestige UPS Model Specifications
120V
Models
Rating Label
Model Number
VA
Watts
Input
Current
(nominal)
Output Current for 120V
Typical Heat
Loss
Line Operation
650
650P1SE
650
455
4.9A
5.4A
74W
650 EXT
650P2SE
650
455
4.9A
5.4A
74W
1250 EXT
1250P2SE
1250
875
9.3A
10.4A
147W
1500 EXT
1500P2SE
1500
1050
11.2A
12.5A
163W
208V-240V
Models
Rating Label
Model Number
VA
Watts
Input
Current
(max)
Output Current for
208V/220V/230V/240V
Typical Heat
Loss
Line Operation
650 EXT
650P2HVSE
650
455
6.0A
3.1/3.0/2.9/2.7A
62W
1250 EXT
1250P2HVSE
1250
875
6.0A
6.0/5.7/5.4/5.2A
123W
1500 EXT
1500P2HVSE
1500
1050
8.0A
7.2/6.8/6.5/6.3A
164W
Prestige UPS Physical Specifications
Parameter
Standard Unit
with Battery
Standard EXT Unit
with Battery
External Battery
Cabinet
PowerPass Distribution
Module
Height
252 mm (9.91”)
252 mm (9.91”)
252 mm (9.91”)
252 mm (9.91”)
Width
142.5 mm (5.61”)
142.5 mm (5.61”)
142.5 mm (5.61”)
142.5 mm (5.61”)
Depth
400 mm (15.75”)
400 mm (15.75”)
400 mm (15.75”)
400 mm (15.75”)
Weight
12.93 kg (28.5 lb)
15.6 kg (34.3 lb)
maximum
EBC60-2 Battery:
22 kg (48.5 lb)
3.8 kg (8.3 lb)