8 SmartWire-DT
8.9 Programming
DS7 Soft starter
09/16 MN03901001Z-EN
www.eaton.com
193
980
ro
DefinedParameters
Unsigned16
Defined parameters:
List of PNUs being used without
subindex.
Each subindex contains a PNU. If
the subindex holds a 0, the end of
the list has been reached.
0 - 65535
–
980
0
ro
U-Start
Unsigned16
Start of list
980
1
ro
U-StartEnd
Unsigned16
980
2
ro
U-StopStart
Unsigned16
980
…
ro
Unsigned16
980
n - 1
ro
DO-Save parameter
Unsigned16
980
n
ro
End of list
Unsigned16
End of list
1) Every time there is a fault, the fault counter’s value will be incremented by one. The corresponding information will be stored in non-volatile
memory and can be used to analyze how many faults have occurred since the fault buffer was last reset. This makes it possible to compare
it to the information obtained the last time the fault buffer was read in order to determine whether the messages in the fault buffer listed
all faults or whether some have already been lost in the stack. As long as the difference between two read operations on the parameters
is smaller than or equal to 8, all previous faults in the fault buffer will be accessible. The mechanism behind the fault buffer can result in
a second or third fault appearing as a subsequent fault after a first fault: In this case, the user will only receive one single piece of
information with the error bit, although there will actually be three new messages. In these cases, the fault counter can help determine
which fault occurred first. DS7-SWD does not support any subsequent fault analyses.
PNU
Index
PNU
Sub-
index
Access
rights
Designation
Data type
Meaning
Value range
DS
User
setting
Содержание DS7 Series
Страница 1: ...Manual DS7 Soft starter 09 16 MN03901001Z EN...
Страница 4: ...II...
Страница 14: ...0 About this Manual 0 8 Units of measurement 10 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Страница 36: ...1 Device series DS7 1 14 Function 32 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Страница 64: ...2 Engineering 2 15 Example of other load cycles 60 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Страница 96: ...3 Installation 3 6 Insulation test 92 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Страница 122: ...6 Parameterization 6 2 Default settings of the basic device 118 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Страница 148: ...7 Connection examples 7 3 Size 3 and 4 41 200 A 144 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Страница 188: ...8 SmartWire DT 8 9 Programming 184 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...