3 Installation
3.6 Electrical Installation
68
DC1-S…20…, DC1-S…OE1 Variable Frequency Drives
05/21 MN040058EN
www.eaton.com
Table 7:
Terminals (IP66)
Size
Connection terminals
Description
FS1
Connection with single-phase supply voltage:
• DC1-S1… (115 V)
• DC1-S2… (230 V)
Hint:
Connection to terminal L3 not permissible!
Motor connection for single-phase AC motor:
• DC1-S1… (115 V)
• DC1-S2… (230 V)
FS2
Connection with single-phase supply voltage:
• DC1-S1… (115 V)
• DC1-S2… (230 V)
Hint:
Connection to terminal L3 not permissible!
Motor connection for single-phase AC motors:
• DC1-S1… (115 V)
• DC1-S2… (230 V)
Hint:
+
,
BR
: Connection for external brake resistors
(
BR
= Output Brake Chopper).
The terminals’ plastic cover can be removed if necessary.
Terminal
+
has the same function as terminal
DC+
in devices with an
IP20 degree of protection.
L1/L
L2/N
L3
⏚
L
N
PE
U
V
W
⏚
PES
M
DC-
L1/L
L2/N
L3
⏚
L
N
PE
PES
DC+
BR
U
V
W
⏚
R
B
M