15
Mounting and operating instructions compact emergency power supply CEAG LP-STAR
40071860247 (L) September 2018 www.ceag.de
Important information
F1-0 2,5A
T F2-0 2,5A
T F3-0 2,5A
T F4-0 2,5A
T
F1-U 2,5A
T F2-U 2,5A
T F3-U 2,5A
T F4-U 2,5A
T
3 .6 .2 CSU 500
Fuses
On the front plate of the unit box can be found
•
1
Downstream fuses 2,5 AT / 250V (2 per circuit) fuse
dimensions: 5 mm x 20 mm, sand filled, order number
40071361235 (packaging unit: 10)
•
2
Mains input fuse 6,3 AT / 250V fuse dimensions:
5 mm x 20 mm, sand filled, order number 40071361234
(packaging unit: 10)
Additional features
• Freely programmable mixed operations between
maintained light, standby lighting and switched maintained
light within a circuit by using CEAG EVGs/modules with
CG-S designation without additional data cables
• Individual monitoring of a maximum of 20 luminaires per
circuit
• Easily accessible fuses
• Connected load per circuit: max. 330 W / max. 345 VA
• Power surge per circuit 250 A each circuit
• Typical switch-over time: AC to DC = 450 ms
ATTENTION!
Only the authorised CEAG Notlichtsysteme GmbH fuses
may be implemented.
2
1
DC
DC
24 V
220 V
4 x 2,5 AT
L1/L2/L3/N/PE