TROUBLESHOOTING
PROBLEM
CAUSE
CORRECTION
Welder Will Not
Power Up
Welder Not Plugged Into Proper Power
Supply
Check power supply. The Elite AC/DC MP200i requires a properly grounded,
240 Volt AC, 50 Amp power supply or a properly grounded 120 Volt AC,
20 Amp power supply.
Facility Power Source Breaker Tripped
Reset breaker.
Welder Breaker Tripped
Reset breaker at rear panel.
Power Switch Not Fully On
Check that Power Switch is fully ON.
Duty Cycle Exceeded
Allow the Welder to cool for a minimum of 15 minutes before attempting to
use again.
Digital Displays
Show: ERR -01-
Output Current Limit Exceeded
Restart the machine and lower the outputs to prevent overloading again.
Digital Displays
Show: ERR -02-
Unit Overheated and Went Into Thermal
Protection Mode
Allow the Welder to cool for a minimum of 15 minutes or until the error display
goes out. If error is still flashing after 15 minutes, restart the Welder.
Digital Displays
Show: ERR -03-
Wire Feeding Malfunction
Contact Eastwood Technical Assistance at 800-343-9353
Digital Displays
Show: ERR -05-
Temperature Sensor Malfunction
Contact Eastwood Technical Assistance at 800-343-9353
Digital Displays
Show: ERR -06-
Unit Switched Off
Momentarily displayed when the unit is switched off. Normal Function.
Power Outage
Momentarily displayed in the event of a power outage. Normal Function.
Wait for power to be restored.
Tripped Breaker
Momentarily displayed when the breaker is tripped. Normal Function.
Reset breaker.
Содержание MP200i
Страница 1: ...AC DC MP200i WELDER ASSEMBLY AND OPERATING INSTRUCTIONS Item 65375 ...
Страница 31: ...To order parts and supplies 800 343 9353 eastwood com 31 DATA CHART ...
Страница 38: ...38 Eastwood Technical Assistance 800 343 9353 tech eastwood com NOTES ...
Страница 39: ...To order parts and supplies 800 343 9353 eastwood com 39 NOTES ...