7
04 No
Rolling.
①
Terminal or Wire Poorly
Contacts.
②
Down-stroke Photo-
Electricity Subassembly Fails.
③
Up-stroke Photo-electricity
Subassembly Fails.
④
Rolling Motor Fails.
⑤
Main PCB Fails.
①
Plug the terminal securely
or replace the wires.
②
Replace Down-Stroke
Subassembly.
③
Replace Up-Stroke Sub-
assembly.
④
Replace Rolling Motor.
⑤
Replace main PCB.
①
Page 23/18
②
&
③
Page 19/8
④
Page 17/6.2
⑤
Page 23/18
05
No kneading.
①
The terminals on main PCB
and wires are poorly
connected.
②
Kneading motor fails.
③
Main PCB fails.
①
Plug the terminal securely
or replace the wires.
②
Replace the kneading
motor.
③
Replace main PCB.
①
&
③
Page 23/18
②
Page 16/6.1
06 No
tapping.
①
The terminals on main
PCB and wires are poorly
connected.
②
Tapping motor fails.
③
Main PCB fails.
①
Plug the terminal securely.
②
Replace the tapping motor.
③
Replace main PCB.
①
&
③
Page 23/18
②
Page 17~18
/6.3
07
No response
when pressing
the keys on the
remote
controller.
①
The terminals and wires are
poorly connected.
②
The PCB in the remote
controller fails.
①
Plug the terminal securely
or replace the wires.
②
Replace the remote
controller.
①
Page 20/11
②
Page 20/10
08
Back rest cannot
be reclined or
raised
①
The terminals of reclining
actuator and wires are poorly
connected.
②
The reclining actuator fails.
③
Main PCB fails.
①
Plug the terminal securely.
②
Replace reclining actuator.
③
Replace main PCB.
①
&
②
Page
21~22/
15
③
Page 23/18
Содержание EC-380B
Страница 3: ...3 I Specifications...
Страница 31: ......
Страница 34: ...3 5V 1 GND 2 PTE6 I O 3 PTE5 I O 4 PTE4 I O 5 PTE3 I O J26 6 5V TJC3S 6A...