13
10. No gas charging in the outer coating of backrest
N
Y
Y
N
N
Y
Y
N
12. No extending or shrinking of the calves-rest
N
Y
N
Y
Y
N
N
Y
N
Common trouble about electric control and processing methods of VT-380 are mentioned above. It is
for indication only.
The terminal of snuffle valves connected
well or not?
The snuffle valves
fail or not?
Plug terminals well
The terminal of the inflator pump
connected well or not?
Replace the snuffle valves
(Page24/19)
Plug terminals well
Replace main PCB
(Page 23/18)
Replace the inflator pump
(Page24/19)
The inflator pump fails or not?
The terminal of the calves-rest
connected well or not?
The wire with terminal connected
well or not?
Plug terminals well
The limit sensor fail or not?
Plug the wire with terminals well
Replace main PCB
(Page 23/18)
Replace the limit sensor
(Page 26/24)
The terminal of the motor connected
well or not?
Plug terminals well
Motor of the calves-rest fails
Replace the motor
(Page 25~26/23)