18
⑤
Then the tapping motor can be removed and replaced.
⑥
Proceed in the reverse order of disassembly when assembly.
7. Maintenance of the massage mechanism
7.1Replacement of the Width Inspection Board
Note
:①
If the massage mechanism is just kneading but no tapping or rolling, or it doesn’t work when power
is on, and the main PCB is ok, in this we can think of that the Width Inspection Board fails.
②
It’s not necessary to disassemble the massage mechanism when replacing the Width Inspection Board,
just disassemble the front and rear cover of the back rest.
①
Disassemble the front and rear cover of the back rest as it is mentioned above.
②
Pull out the terminal on the board and cut the cable ties fixing the wires.
③
Remove the screws securing the board, then a new one can be replaced.
④
Proceed in the reverse order of disassembly when assembly.
Tools:
a plus screwdriver, wire cutters
7.2 Disassembly and replacement of the massage mechanism
Note:
If the swinging arms are broken or it is too noisy, you can try to do something to the massage
mechanism. You should disassemble the rear cover and the cloth of the back rest.
①
Disassemble the rear cover of back rest, remove the back pad, and disassemble the cloth of the back
rest, cut all the cable ties tightening the wires.
②
Remove the close-end wire connectors of tapping motor wires, then disconnect the wires.
③
Pull out the terminals of the Width Inspection Board, 3 PCS.
④
Take down the belt of tapping motor, then disassemble the tapping motor. Remove the screws securing
the massage mechanism on the running frame and the screws securing nylon clamp which fixes wires.
⑤
Adjust the position of the massage mechanism and the width of the swinging arms, until the massage
mechanism is taken off.
Close-end wire connector of tapping motor
1 terminals on the board
Screws(2pcs)securing the board