8. Replacement of up or down stroke photo-electricity assembly
①
Disassemble the rear cover of the back rest.
②
Pull out the terminal of the wire.
③
Remove the screws tightening the PCB of up or down stroke photo-electricity assembly
to the sheet-metal with a plus screwdriver and nipper pliers.
④
Proceed in the reverse order of disassembly when replacement needed.
Tools: a plus screwdriver and nipper pliers
Screws securing the mechanism
Massage mechanism taken down
Remove the screws
(3pcs)
The terminal of
the wire
Adjust the position of the massage
mechanism and the width of the
swinging arms