PROGRAMMING
3-11
Revised January 2001
Part No. 001-7780-501
Penalty Timer - This timer disables transmitting
after the time-out timer expires (Section 2.4.7).
Times up to 3 minutes, 45 seconds in 15-second
steps can be programmed.
Conversation Timer - This timer limits the total
length of a conversation (Section 2.4.8). Times up to
7.5 minutes in 0.5-minute steps can be programmed.
Conventional System General Screen
Busy Channel Override - Selects if the busy channel
lockout feature can be overridden by quickly releasing
and then pressing the PTT switch (see Section 2.4.5).
Conventional System Scan List Screen
Scan List Button
Clicking Scan List in the left pane or that button
in the General screen displays the preceding screen
which is used to program the conventional scan lists
described in Section 2.4.11.
NOTE: The conventional scan lists cannot be
programmed until all the conventional channels are
programmed. Therefore, first program the channels as
described in Sections 3.5.3 and 3.5.4.
To modify a list, click
and the
screen which follows is displayed. Select the desired
scan list in the box on the top and then select the zone
and the channels from that zone to be included. Repeat
for each zone. Do this for each list programmed. The
button deletes the selected channel(s)
from the scan list.
Conventional System Modify Scan List Screen
The following parameters are programmed in the
Conventional System Scan List Screen shown on the
left.
Keypad Editing
This function selects if the user is allowed to edit
the scan list. This requires the Scan Edit option switch