PROGRAMMING
3-20
Revised January 2001
Part No. 001-7780-501
Trunking Call List Screen
This screen allows the list of IDs used for private
calls to be programmed. A maximum of 16 IDs can be
programmed (see Sections 2.5.4 and 2.5.5).
To edit this list, click the Trunking Call List tab
and then the “Modify List” button on the right side.
This following information is then programmed in the
dialog box that is displayed:
Entry Number - This box selects the entry to be
edited. The scroll bars to the right of this box select
the desired entry. A private call list can contain up to
16 entries. Selecting a new entry number automati-
cally validates and stores the current entry. If the
current entry contains an invalid field, the entry
number does not change and the invalid field is
highlighted.
Entry Alias - Up to 8 characters can be entered to
identify the user being called. This identification is
displayed when the mobile to be called is selected
by the user from the list. Only uppercase letters can
be entered, so lowercase letters are automatically
converted to uppercase by the program.
Call ID - This is the ID of the radio being called.
Valid entries are 1-65535. A “0” is detected as no
entry.
Close Button - Verifies the current entry, stores it,
and then closes the dialog box. If the current entry
contains an invalid field, the dialog box does not
close and the invalid field is highlighted.
Priority Monitor Scan Screen
This screen programs up to three Priority Monitor
scan lists that are allowed. Each scan list can contain
up to 15 channels plus a priority channel (see Section
2.5.12). These channels must be from the same
SMARTNET/SmartZone system. Channels set up for
other systems are not allowed.
To edit a list, click the Priority Monitor Scan tab
and then click the “Modify List” button on the right
side. A screen similar to the bottom screen shown
above is then displayed to select the channels to be
included in that scan list. Select channels as follows:
1. Select the scan list to be edited by clicking the scroll
bars next to the “Scan List To Modify” box.
2. Select the first zone with channels to be included
and select the desired channels. Repeat for the other
zones.
3. To select the priority channel, click the Set Priority
button. Then select the desired Zone/Channel or
“None” if no priority channel is to be scanned.