Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com
70
HYDRAULIC GENERATORS
TECHNICAL SPECIFICATIONS
STANDARD MODELS* 60HZ
HG 18
HG 25
HG 40
OUTPUT CHARACTERISTICS
Output power max.
kVA
18
25
40
Output Voltage****
V
120/208 VAC
120/208 VAC
120/208 VAC
Nominal Current *
1~phase / 3~phase
A
74,85 / 49,9
103,9 / 69,3
166,5 / 111,0
Frequency
Hz
60
60
60
Phase
1/3
1/3
1/3
IP
23
23
23
Voltage regulator
AVR
AVR
AVR
Sockets
(1 phase / 3 phase / cable K)
2 / 2 /-
2 / 2 /-
- / - /K
HYDRAULIC CONNECTION
Pressure line P
P
BSP 3/4”
BSP 3/4”
BSP 3/4”
Return line T
T
BSP 1”
BSP 1”
BSP 3/4”
Drain line D
D
BSP 1/4"
BSP 1/4"
M22x1,5
HYDRAULIC POWER REQUIREMENTS
Flow min.
l/min
(gpm)
80 (21.2)
112 (29.6)
112 (29.6)
Flow max.
l/min
(gpm)
98 (25.8)
130 (34.3)
128 (33.7)
Pressure at nominal power output
bar
(psi)
180 (2600)
180 (2600)
280 (4100)
Pressure max.
bar
(psi)
210 (3000)
210 (3000)
420 (6100)
Pressure when unloaded
bar
(psi)
35 (510)
50 (730)
40 (580)
HYDRAULIC FLUID REQUIREMENTS
Viscosity
cSt
10-200 / optimum 25-35
Temperature
°C(°F)
max. 70 (158)**
Filter ratio
μm
25 or better
Cooling capacity requirements ***
kW
4,5
5,9
9,1
OVERALL DIMENSIONS
Length
mm
(in)
828 (32.6)
879 (35.2)
989 (38.95)
Width
mm
(in)
349 (13.75)
349 (13.75)
384 (15.7)
Height
mm
(in)
366 (14.45)
366 (14.45)
478 (18.85)
Weight
kg
(lbs)
98 (216)
120 (265)
198 (437)
Gallons are U.S. liquid gallons.
* Nominall current (1~phase / 3~phase) /phase. Must not exceed maximum load.
** Ref. to the hydraulic fluid in chapter 6.2.
*** Minimum cooling capacity for HG hydraulic generator on base machine.
**** 60 Hz HG Hydraulic Generators are available with any standard 60 Hz voltage system by request.