Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com
69
HYDRAULIC GENERATORS
TECHNICAL SPECIFICATIONS
STANDARD MODELS 60HZ
HG 3,7
HG 6
HG 9
HG 12
OUTPUT CHARACTERISTICS
Output power max.
kVA
3,7
6
9
12
Output Voltage*****
V
120 VAC
120 VAC
120/208 VAC 120/208VAC
Nominal Current *
1~phase / 3~phase
A
37,5 /-
50 /-
37,35 / 24,9
49,9 / 33,3
Frequency
Hz
60
60
60
60
Phase
1/3
1
1
1/3
IP
23
23
23
23
Voltage regulator
Capasitor
Compound
Compound
AVR
Sockets
(1 phase / 3 phase / cable K)
2 / - / -
2 / - / -
2 / 1 / -
2 / 1 / -
HYDRAULIC CONNECTION
Pressure line P
P
BSP 1/2”
BSP 1/2”
BSP 1/2”
BSP 3/4”
Return line T
T
BSP 1/2”
BSP 1/2”
BSP 1/2”
BSP 1/2”
Drain line D
D
6L - (M12x1,5
Male)
6L - (M12x1,5
Male)
6L - (M12x1,5
Male)
6L - (M12x1,5
Male)
HYDRAULIC POWER REQUIREMENTS
Flow min.
l/min
(gpm)
27 (7.2)
32 (8.5)
43 (11.4)
60 (15.9)
Flow max.
l/min
(gpm)
40 (10.5)
49 (12.9)
60 (15.8)
78 (21.6)
Pressure at nominal power output
bar
(psi)
160 (2300)
160 (2300)
180 (2600)
180 (2600)
Pressure max.
bar
(psi)
210 (3000)
210 (3000)
210 (3000)
210 (3000)
Pressure when unloaded
bar
(psi)
40 (580)
40 (580)
30 (440)
30 (440)
HYDRAULIC FLUID REQUIREMENTS
Viscosity
cSt
10-200 / optimum 25-35
Temperature
°C(°F)
max. 70 (158)**
Filter ratio
μm
25 or better
Cooling capacity
requirements ***
kW
1,5
2
2,7
3,7
OVERALL DIMENSIONS
Length
mm
(in)
458 (18.0)
459 (18.1)
583 (23.0)
587 (23.1)
Width
mm
(in)
212 (8.3)
212 (8.3)
290 (11.4)
290 (11.4)
Height
mm
(in)
230 (9.0)
230 (9.0)
368 (14.5)
368 (14.5)
Weight
kg
(lbs)
29 (64)
29 (64)
104 (229)
60 (132)