Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com
47
HYDRAULIC GENERATORS
MAINTENANCE
6. MAINTENANCE
DYNASET HG hydraulic generators are low-maintenance units. Only normally
wearing parts and materials should be replaced either when necessary or in
accordance with a service program.
ATTENTION!
Before beginning any maintenance or repair, ensure that the system
is stopped and depressurized. Make sure that the system can not start
accidentally.
6.1. MAINTENANCE INTERVALS
All maintenance must be complied with as they are scheduled in this manual.
The following table provides maintenance schedule for DYNASET HG hydraulic
generator.
CHECK POINTS
NEW DEVICE AFTER
INSTALLATION
AFTER
DAILY USE
MONTHLY
Perform the needed actions after HG’s
installation according to the chapter
4.
Installation.
x
Check if the HG hydraulic generator
needs cleaning and clean it according to
the chapter 6.3.
x
Test safety devices
x
6.2. HYDRAULIC FLUIDS
A wide range of standard hydraulic fluids can be used with the DYNASET hydraulic
equipment. Depending on the operating temperature, the following mineral
hydraulic oils are recommended:
MINERAL HYDRAULIC OIL
OPERATION TEMPERATURE UP TO
ISO VG 32S
60 °C
ISO VG 46S
70 °C
ISO VG 68S
80 °C
NOTE!
Recommended oil viscosity is between 10 to 35 cSt when operating at
normal operating temperature.
Synthetic and bio-oils can also be used if their viscosity characteristics and
lubricating efficiency are similar to the mineral oils. Automatic transmission fluids
and even engine oils can be used, provided that they are allowed to be used in
hydraulic system of your base machine.
Содержание HG 1
Страница 2: ......
Страница 71: ...DYNASET OY all rights reserved...